SG2500HV-MV/SG3000HV-MV
Sales Area
APACEMEASAAF
High Yield
Efficient three-level topology, max. inverter
efficiency up to 99 %
1 or 2 MPPT, wide MPP voltage range
Full power operation without derating at 50 ℃
One inverter unit fails, the other unit continues
operation
Easy O&M
Integrated zone current monitoring function for
fast trouble shooting
Module design and front service, easy for
maintenance
DC circuit breaker design for convenient
maintenance
Saved Investment
DC 1500 V system, low system initial investment
20-foot container design, no need to build extra
inverter house
Integrated MV transformer and LV auxiliary power
supply
Grid Support
Compliance with standards: CE, IEC 62109
Low/High voltage ride through (L/HVRT)
Active & reactive power control and power
ramp rate control

Technical Data
Input (DC) SG2500HV-MV SG3000HV-MV
Max. PV input voltage 1500 V  
Min. PV input voltage / Startup input voltage 800 V / 840 V 900 V / 940 V
MPP voltage range for nominal power 800 – 1300 V 900 – 1300 V
No. of independent MPP inputs 1 or 2  
No. of DC inputs 16 – 24  
Max. PV input current 3508 A  
Max. DC short-circuit current 4210 A  
Output (AC)
Nominal AC power 2500 kW (at 50 ˚C) 3000 kW (at 50 ˚C)
Max. AC output at PF=1 2750 kW (at 45 ˚C) 3000 kW (at 50 ˚C)
Max. AC apparent power 2750 kVA (at 45 ˚C) 3000 kVA (at 50 ˚C)
Max. inverter output current 2886 A  
AC voltage range 10 – 35 kV  
Nominal grid frequency / Grid frequency range 50 Hz / 45 – 55 Hz, 60 Hz / 55 – 65 Hz  
THD < 3 % (at nominal power)  
DC current injection < 0.5 % In  
Power factor at nominal power / Adjustable power factor > 0.99 / 0.8 leading - 0.8 lagging  
Feed-in phases / Connection phases 3 / 3  
Efficiency
Inverter max. efficiency / Inverter Euro efficiency 99.0 % / 98.7 %
Transformer
Transformer rated power 2500 kVA 3000 kVA
Transformer Max.power 2750 kVA 3000 kVA
Input / Output Voltage 0.55 kv / 10 – 35 kv 0.6 kV / 10 – 35 kV
Transformer Vector Dy11
Oil type Mineral oil (PCB free),or degradable oil on request
Protection
DC reverse connection protection Yes
DC input protection Circuit breaker
Inverter output protection Circuit breaker
AC output protection Circuit breaker * / Load switch + fuse **
Overvoltage protection DC Type II / AC Type II
Grid monitoring / Ground fault monitoring Yes / Yes
Insulation monitoring Yes
Overheat protection Yes
Anti-PID function Optional
General Data
Dimensions (W*H*D) 6058*2896*2438 mm
Weight 17 T
Degree of protection IP54
Auxiliary power supply 220 Vac, 2 kVA / Optional: 380 Vac, up to 15 kVA
Operating ambient temperature range -35 to 60 ℃ (> 50 ℃ derating) 
Allowable relative humidity range (non-condensing) 0 – 95 %
Cooling method Temperature controlled forced air cooling
Max. operating altitude 1000 m (standard) / > 1000 m (optional)
Display Touch screen
Communication Standard: RS485, Ethernet; Optional: Optical fiber
Compliance CE, IEC 62109
Grid support LVRT, HVRT, active & reactive power control and power ramp rate control
Type designation SG2500HV-MV-S-10/SG2500HV-MV-C-10 SG3000HV-MV-S-10 /SG3000HV-MV-C-10
*:available for SG2500HV-MV-S-10/SG3000HV-MV-S-10
**:available for SG2500HV-MV-C-10/SG3000HV-MV-C-10