SG2500HV/SG3000HV
Sales Area
APACEMEAINSAAF
High Yield
Efficient three-level topology, max. inverter
efficiency up to 99 %
1 or 2 MPPT, wide MPP voltage range
Full power operation without derating at 50 ℃
One inverter unit fails, the other unit continues
operation
Easy O&M
Integrated zone current monitoring function for
fast trouble shooting
Module design and front service, easy for
maintenance
DC circuit breaker design for convenient
maintenance
Saved Investment
DC 1500 V system, low system initial investment
10-foot container design, no need to build extra
inverter house
Integrated LV auxiliary power supply
Grid Support
Compliance with standards: IEC 62109, IEC
61727, IEC 62116, CE, G59/3
Low/High voltage ride through (L/HVRT)
Active & reactive power control and power
ramp rate control

Technical Data
Input (DC) SG2500HV SG3000HV
Max. PV input voltage 1500 V  
Min. PV input voltage / Startup input voltage 800 V / 840 V 900 V / 940 V
MPP voltage range for nominal power 800 – 1300 V 900 – 1300 V
No. of independent MPP inputs 1 or 2  
No. of DC inputs 16 – 24  
Max. PV input current 3508 A  
Max. DC short-circuit current 4210 A  
Output (AC)
Nominal AC power 2500 kW (at 50 ˚C) 3000 kW (at 50 ˚C)
Max. AC output at PF=1 2750 kW (at 45 ˚C) 3000 kW (at 50 ˚C)
Max. AC apparent power 2750 kVA (at 45 ˚C) 3000 kVA (at 50 ˚C)
Max. inverter output current 2886 A  
Nominal AC voltage 550 V 600 V
AC voltage range 440 – 632 V 480 – 690 V
Nominal grid frequency / Grid frequency range 50 Hz / 45 – 55 Hz, 60 Hz / 55 – 65 Hz  
THD < 3 % (at nominal power)  
DC current injection < 0.5 % In  
Power factor at nominal power / Adjustable power factor > 0.99 / 0.8 leading – 0.8 lagging  
Feed-in phases / Connection phases 3 / 3  
Efficiency
Inverter max. efficiency / Inverter Euro efficiency 99.0 % / 98.7 %
Protection
DC reverse connection protection Yes
DC input protection Circuit breaker
AC output protection Circuit breaker
Overvoltage protection DC Type II / AC Type II
Grid monitoring / Ground fault monitoring Yes / Yes
Insulation monitoring Yes
Overheat protection Yes
Anti-PID function Optional
General Data



Dimensions (W*H*D) 2991*2591*2438 mm 
Weight 5.9 T 
Isolation method Transformerless
Degree of protection IP54
Auxiliary power supply 220 Vac, 2 kVA / Optional: 380 Vac, up to 15 kVA
Operating ambient temperature range -35 to 60 ℃ (> 50 ℃ derating) 
Allowable relative humidity range (non-condensing) 0 - 95 %
Cooling method Temperature controlled forced air cooling
Max. operating altitude 4500 m (> 3500 m derating)  4000 m (> 2000 m derating) 
Display Touch screen
Communication Standard: RS485, Ethernet; Optional: Optical fiber
Compliance CEA, IEC 62109, IEC 61727, IEC 62116, IEC 60068, IEC 61683, CE, G59/3
Grid support LVRT, HVRT, active & reactive power control and power ramp rate control
Type designation SG2500HV-10 SG3000HV-10