SG80KTL
Sales Area
EMEAIN
High Yield
Max. efficiency 98.9 %, European efficiency 98.7 %
Full power operation without derating at 50 ℃
Easy O&M
Integrated string current monitoring function for
fast trouble shooting
Compact design and light weight for easy installation
Plug-in design of fan and SPD, convenient for on-site maintenance
Saved Investment
Max. DC/AC ratio more than 1.4
Integrated DC combiner box and DC/AC overvoltage protection
Grid Support
Compliance with standards: CE, BDEW, VDE-AR-N 4120, IEC 62109, IEC 61727, IEC 62116
Low/High voltage ride through (L/HVRT)
Active & reactive power control and power ramp rate control

Technical Data
Inpt (DC) SG80KTL
Max PV input voltage 1100 V
Min. PV input voltage / Startup input voltage 570 V / 620 V
Nominal input voltage 710 V
MPP voltage range 570 – 950 V
MPP voltage range for nominal power 570 – 850 V
No. of independent MPP inputs 1
Max. number of PV strings per MPPT 18
Max. PV input current 144 A
Max. current for input connector 12 A
Max. DC short-circuit current 200 A
Output (AC)
Nominal AC power (at 50 ˚C) 80000 W
Max. AC output at PF=1 (at 50 ˚C) 80000 W
Max. AC apparent power (at 50 ˚C) 80000 VA
Max. AC output current 116 A
Nominal AC voltage 3 / PE, 230 / 400 V
AC voltage range 310 – 480 V
Nominal grid frequency / Grid frequency range 50 Hz / 45 – 55 Hz, 60 Hz / 55 – 65 Hz
THD < 3 % (at nominal power)
DC current injection < 0.5 % In
Power factor at nominal powe / Adjustable power factor > 0.99 / 0.8 leading – 0.8 lagging
Feed-in phases / Connection phases 3 / 3
Efficiency
Max. efficiency / Euro. efficiency 98.9 % / 98.7 %
Protection
DC reverse connection protection Yes
AC short-circuit protection Yes
Leakage current protection Yes
Grid monitoring Yes
DC switch / AC switch Yes / No
DC fuse Yes (positive, 15A)
PV string current monitoring Yes
Overvoltage protection DC Type II / AC Type II
General Data
Dimensions (W*H*D) 634*932*267 mm 
Weight 65 kg 
Isolation method Transformerless
Degree of protection IP65
Night power consumption < 4 W
Operating ambient temperature range -25 to 60 ℃ (> 50 ℃ derating)
Allowable relative humidity range (non-condensing) 0 – 100 %
Cooling method Smart forced air cooling
Max. operating altitude 4000m (>3000m derating)
Display / Communication Graphic LCD / RS485
DC connection type MC4 (Max. 6mm²)
AC connection type Screw clamp terminal (Max. 150 mm² )
Compliance CEA, IEC 62109, IEC 61727, IEC 62116, IEC 60068,
IEC 61683, CE, BDEW, VDE-AR-N 4120
Grid support LVRT, HVRT, active & reactive power control and power ramp rate control
Type designation SG80KTL-10