SG2500HV

SG2500HV

Technical Data

Efficiency
Max. efficiency / Euro. efficiency 99.0 % / 98.7 %
General Data
Dimensions (W*H*D) 2991*2591*2438 mm
Weight 5.9 T
Isolation method Isolation method
Degree of protection IP54
Auxiliary power supply 220 Vac, 2 kVA / Optional: 415 Vac, up to 40 kVA
Operating ambient temperature range -35 to 60 ℃ (> 50 ℃ derating)
Allowable relative humidity range (non-condensing) 0 – 95 %
Cooling method Temperature controlled forced air cooling
Max. operating altitude 4500 m (> 3500 m derating)
Display Touch screen
Communication Standard: RS485, Ethernet; Optional: optical fiber
Compliance IEC 62109, IEC 61727, IEC 62116, IEC 60068, IEC 61683, CE, G59/3,CEA
Grid support LVRT, HVRT, active & reactive power control and power ramp rate control
Type designation SG2500HV-10
Input (DC)
Max. PV input voltage 1500V
Min. PV input voltage / Startup input voltage 800 V / 840 V
MPP voltage range for nominal power 800 – 1300 V
No. of independent MPP inputs 1 or 2
No. of DC inputs 16 – 24
Max. PV input current 3508 A
Max. DC short-circuit current 4210 A
Output (AC)
AC output power 2750 kVA @ 45 ˚C / 2500 kVA @ 50 ˚C
Max. AC output current 2886 A
Nominal AC voltage 550 V
AC voltage range 440 – 632 V
Nominal grid frequency / Grid frequency range 50 Hz / 45 – 55 Hz, 60 Hz / 55 – 65 Hz
THD < 3 % (at nominal power)
DC current injection < 0.5 % In
Power factor at nominal power / Adjustable power factor > 0.99 / 0.8 leading – 0.8 lagging
Feed-in phases / Connection phases 3 / 3
Protection
DC reverse connection protection Yes
DC input protection Circuit breaker
AC output protection Circuit breaker
Overvoltage protection DC Type II / AC Type II
Grid monitoring / Ground fault monitoring Yes / Yes
Insulation monitoring Yes
Overheat protection Yes
Anti-PID function Optional
SG2500HV

SG2500HV

Technical Specifications

Efficiency
Max. efficiency / Euro. efficiency 99.0 % / 98.7 %
General Data
Dimensions (W*H*D) 2991*2591*2438 mm
Weight 5.9 T
Isolation method Isolation method
Degree of protection IP54
Auxiliary power supply 220 Vac, 2 kVA / Optional: 415 Vac, up to 40 kVA
Operating ambient temperature range -35 to 60 ℃ (> 50 ℃ derating)
Allowable relative humidity range (non-condensing) 0 – 95 %
Cooling method Temperature controlled forced air cooling
Max. operating altitude 4500 m (> 3500 m derating)
Display Touch screen
Communication Standard: RS485, Ethernet; Optional: optical fiber
Compliance IEC 62109, IEC 61727, IEC 62116, IEC 60068, IEC 61683, CE, G59/3,CEA
Grid support LVRT, HVRT, active & reactive power control and power ramp rate control
Type designation SG2500HV-10
Input (DC)
Max. PV input voltage 1500V
Min. PV input voltage / Startup input voltage 800 V / 840 V
MPP voltage range for nominal power 800 – 1300 V
No. of independent MPP inputs 1 or 2
No. of DC inputs 16 – 24
Max. PV input current 3508 A
Max. DC short-circuit current 4210 A
Output (AC)
AC output power 2750 kVA @ 45 ˚C / 2500 kVA @ 50 ˚C
Max. AC output current 2886 A
Nominal AC voltage 550 V
AC voltage range 440 – 632 V
Nominal grid frequency / Grid frequency range 50 Hz / 45 – 55 Hz, 60 Hz / 55 – 65 Hz
THD < 3 % (at nominal power)
DC current injection < 0.5 % In
Power factor at nominal power / Adjustable power factor > 0.99 / 0.8 leading – 0.8 lagging
Feed-in phases / Connection phases 3 / 3
Protection
DC reverse connection protection Yes
DC input protection Circuit breaker
AC output protection Circuit breaker
Overvoltage protection DC Type II / AC Type II
Grid monitoring / Ground fault monitoring Yes / Yes
Insulation monitoring Yes
Overheat protection Yes
Anti-PID function Optional