SG2500HV-MV

SG2500HV-MV

High Yield
  • Efficient three-level topology, max. inverter efficiency up to 99 %
  • 1 or 2 MPPT, wide MPP voltage range
  • Full power operation without derating at 50 ℃
  • One inverter unit fails, the other unit continues operation
High Yield
  • Efficient three-level topology, max. inverter efficiency up to 99 %
  • 1 or 2 MPPT, wide MPP voltage range
  • Full power operation without derating at 50 ℃
  • One inverter unit fails, the other unit continues operation
Easy O&M
  • Integrated zone current monitoring function for fast trouble shooting
  • Module design and front service, easy for maintenance
  • DC circuit breaker design for convenient maintenance
Saved Investment
  • DC 1500 V system, low system initial investment
  • 20-foot container design, no need to build extra inverter house
  • Integrated MV transformer and LV auxiliary power supply
Grid Support
  • Compliance with standards: CE, IEC 62109
  • Low/High voltage ride through (L/HVRT)
  • Active & reactive power control and power ramp rate control
High Yield
  • Efficient three-level topology, max. inverter efficiency up to 99 %
  • 1 or 2 MPPT, wide MPP voltage range
  • Full power operation without derating at 50 ℃
  • One inverter unit fails, the other unit continues operation

Technical Data

Efficiency
Inverter max. efficiency / Inverter Euro. efficiency 99.0 % / 98.7 %
General Data
Dimensions (W*H*D) 6058*2896*2438 mm
Weight 17 T
Degree of protection IP54
Auxiliary power supply 415 Vac, 15 kVA / Optional: 415 Vac, up to 40 kVA
Operating ambient temperature range -35 to 60 ℃ (> 50 ℃ derating)
Allowable relative humidity range (non-condensing) 0 – 95 %
Cooling method Temperature controlled forced air cooling
Max. operating altitude 1000 m (standard) / > 1000 m (optional)
Display Touch screen
Communication Standard: RS485, Ethernet; Optional: optical fiber
Compliance CE, IEC 62109
Grid support LVRT, HVRT, active & reactive power control and power ramp rate control
Type designation SG2500HV-MV-S-10/SG2500HV-MV-C-10
Input (DC)
Max. PV input voltage 1500V
Min. PV input voltage / Startup input voltage 800 V / 840 V
MPP voltage range for nominal power 800 – 1300 V
No. of independent MPP inputs 1 or 2
No. of DC inputs 16 – 24
Max. PV input current 3508 A
Max. DC short-circuit current 4210 A
PV array configuration Negative grounding or floating
Output (AC)
AC output power 2750 kVA @ 45 ˚C / 2500 kVA @ 50 ˚C
Max. inverter output current 2886 A
AC voltage range 10 – 35 kV
Nominal grid frequency / Grid frequency range 50 Hz / 45 – 55 Hz, 60 Hz / 55 – 65 Hz
THD < 3 % (at nominal power)
DC current injection < 0.5 % In
Power factor at nominal power / Adjustable power factor > 0.99 / 0.8 leading – 0.8 lagging
Feed-in phases / Connection phases 3 / 3
Protection
DC reverse connection protection Yes
DC input protection Circuit breaker
Inverter output protection Circuit breaker
AC output protection Circuit breaker
Overvoltage protection DC Type II / AC Type II
Grid monitoring / Ground fault monitoring Yes / Yes
Insulation monitoring Yes
Overheat protection Yes
Anti-PID function Optional
Transformer
Transformer rated power 2500 kVA
Transformer max. power 2750 kVA
LV / MV voltage 0.55 kV / 10 – 35 kV
Transformer vector Dy11
Transformer cooling type ONAN (Oil Natural Air Natural)
Oil type Mineral oil (PCB free) or degradable oil on request
SG2500HV-MV

SG2500HV-MV

High Yield
  • Efficient three-level topology, max. inverter efficiency up to 99 %
  • 1 or 2 MPPT, wide MPP voltage range
  • Full power operation without derating at 50 ℃
  • One inverter unit fails, the other unit continues operation
High Yield
  • Efficient three-level topology, max. inverter efficiency up to 99 %
  • 1 or 2 MPPT, wide MPP voltage range
  • Full power operation without derating at 50 ℃
  • One inverter unit fails, the other unit continues operation
Easy O&M
  • Integrated zone current monitoring function for fast trouble shooting
  • Module design and front service, easy for maintenance
  • DC circuit breaker design for convenient maintenance
Saved Investment
  • DC 1500 V system, low system initial investment
  • 20-foot container design, no need to build extra inverter house
  • Integrated MV transformer and LV auxiliary power supply
Grid Support
  • Compliance with standards: CE, IEC 62109
  • Low/High voltage ride through (L/HVRT)
  • Active & reactive power control and power ramp rate control
High Yield
  • Efficient three-level topology, max. inverter efficiency up to 99 %
  • 1 or 2 MPPT, wide MPP voltage range
  • Full power operation without derating at 50 ℃
  • One inverter unit fails, the other unit continues operation

Technical Specifications

Efficiency
Inverter max. efficiency / Inverter Euro. efficiency 99.0 % / 98.7 %
General Data
Dimensions (W*H*D) 6058*2896*2438 mm
Weight 17 T
Degree of protection IP54
Auxiliary power supply 415 Vac, 15 kVA / Optional: 415 Vac, up to 40 kVA
Operating ambient temperature range -35 to 60 ℃ (> 50 ℃ derating)
Allowable relative humidity range (non-condensing) 0 – 95 %
Cooling method Temperature controlled forced air cooling
Max. operating altitude 1000 m (standard) / > 1000 m (optional)
Display Touch screen
Communication Standard: RS485, Ethernet; Optional: optical fiber
Compliance CE, IEC 62109
Grid support LVRT, HVRT, active & reactive power control and power ramp rate control
Type designation SG2500HV-MV-S-10/SG2500HV-MV-C-10
Input (DC)
Max. PV input voltage 1500V
Min. PV input voltage / Startup input voltage 800 V / 840 V
MPP voltage range for nominal power 800 – 1300 V
No. of independent MPP inputs 1 or 2
No. of DC inputs 16 – 24
Max. PV input current 3508 A
Max. DC short-circuit current 4210 A
PV array configuration Negative grounding or floating
Output (AC)
AC output power 2750 kVA @ 45 ˚C / 2500 kVA @ 50 ˚C
Max. inverter output current 2886 A
AC voltage range 10 – 35 kV
Nominal grid frequency / Grid frequency range 50 Hz / 45 – 55 Hz, 60 Hz / 55 – 65 Hz
THD < 3 % (at nominal power)
DC current injection < 0.5 % In
Power factor at nominal power / Adjustable power factor > 0.99 / 0.8 leading – 0.8 lagging
Feed-in phases / Connection phases 3 / 3
Protection
DC reverse connection protection Yes
DC input protection Circuit breaker
Inverter output protection Circuit breaker
AC output protection Circuit breaker
Overvoltage protection DC Type II / AC Type II
Grid monitoring / Ground fault monitoring Yes / Yes
Insulation monitoring Yes
Overheat protection Yes
Anti-PID function Optional
Transformer
Transformer rated power 2500 kVA
Transformer max. power 2750 kVA
LV / MV voltage 0.55 kV / 10 – 35 kV
Transformer vector Dy11
Transformer cooling type ONAN (Oil Natural Air Natural)
Oil type Mineral oil (PCB free) or degradable oil on request