SC60HV

Sales Area
USA & Canada
High Yield
Advanced three-level technology, max. efficiency 98.6%
Effective forced air cooling, 1.1 overload capacity, no derating up to 122 °F
Wide DC voltage operation window, flexible for battery configuration
Easy O&M
Compact design and light weight for easy installation
Easy site commissioning & monitoring via APP
Scalable system configuration, extend to MW power range
ESS Applications
Battery charge & dis-charge management integrated
Bidirectional power conversion system with full fourquadrant operation
EPS function design, can support the electrical equipment when the power grid fails
Compatible with high voltage battery system, low system cost
Grid Support
Complies with UL 1741, UL 1741 SA
Grid support including L/HVRT, soft start/stop, specified power factor control and reactive power support

Technical Data

DC side
Max. DC voltage 1500 V
Min. DC voltage 700 V
DC voltage range for nominal power 700 – 1300 V
Max. DC current 96.6 A
Max. DC power 67.5 kW
AC side (Grid)
AC output power 66 kVA @ 45 ˚C (113 °F) / 60 kVA @ 50 ˚C (122 °F)
Max. AC current 79.3 A
Nominal AC voltage 480 V
AC voltage range 422.4 – 528 V
Nominal grid frequency / Grid frequency range 60 Hz / 55 – 65 Hz
AC current THD < 3 % (at nominal power)
DC current injection < 0.5 % In
Power factor at nominal power > 0.99
Adjustable reactive power -100% – 100%
AC side (Off-Grid)
Nominal AC voltage 480 V ± 3 %
AC voltage THD < 3 % (Linear load)
Nominal grid frequency / Grid frequency range 60 Hz / 55 - 65 Hz
AC output power 66 kVA @ 45 ℃ / 60 kVA @ 50 ℃
Efficiency
Max. charge efficiency 98.5 %
Max. discharge efficiency 98.6 %
Protection
Reverse polarity protection Yes
DC switch Yes
AC switch Yes
Overvoltage protection DC Type II / AC Type II
Grid monitoring / Ground fault monitoring Yes / Yes
Insulation monitoring Yes
Overheat protection Yes
General Data
Dimensions (W*H*D) 600*800*278 mm (23.6''*31.5''*11.0'')
Weight 75 kg (165.3 lbs)
Isolation method Transformerless
Degree of protection NEMA 4X
Operating ambient temperature range -25 to 60 ˚C (> 50 ˚C derating) (-13 to 140 ℉ (> 122 ℉ derating))
Allowable relative humidity range (non-condensing) 0 – 100 %
humidity range (non-condensing) Temperature controlled forced air cooling
Max. operating altitude 4000 m (> 3000 m derating) (13123 ft (> 9843 ft derating))
Display LED, Bluetooth + APP
Self-consumption at stop < 20 W
Communication RS485 / Ethernet / CAN
Communication protocol Modbus-RTU / Modbus-TCP, CAN2.0B
Compliance UL 1741, UL 1741 SA, Rule 21
Grid support L/HVRT, active & reactive power control and power ramp rate control
Type designation SC60HV-10

Product Consultation

Online Consulting