SG5KTL-MT/SG6KTL-MT/ SG8KTL-M

Technical Data

Input (DC) SG5KTL-MT SG6KTL-MT SG8KTL-M
Max. PV input voltage 1100 V
Min. PV input voltage / Start-up input voltage 200 V / 250 V
Nominal PV input voltage 600 V
MPP voltage range 200 – 1000 V
MPP voltage range for nominal power 240 – 850 V 290 – 850 V 380 – 850 V
No. of independent MPP inputs 2
Max. number of PV strings per MPPT 1
Max. PV input current 22A (11A / 11A)
Max. current for input connector 15 A
Max. DC short-circuit current 30 A (15A / 15A )
Output (AC)      
Nominal AC power(at 45 ℃) 5000 W 6000 W 8000 W
Max. AC power when PF = 1 (at 35 ℃) 5500 W 6600 W 8800 W
Max. AC apparent power (at 35 ℃) 5500 W 6600 W 8800 W
Max. AC output current (at 35 ℃) 8.5A 10.0 A 13.3 A
Nominal AC voltage 3 / N / PE, 230 / 400 V
AC voltage range 270 - 480 V
Nominal grid frequency / Grid frequency range 50 Hz / 45 - 55 Hz, 60 Hz / 55 - 65 Hz
THD < 3 % (at nominal power)
DC current injection < 0.5 % In
Power factor at nominal power >0.99
Ajustable power factor 0.8 leading - 0.8 lagging
Feed-in phases / connection phases 3 / 3
Efficiency      
Max. efficiency / European efficiency 98.2% / 97.6% 98.4% / 97.7% 98.6% / 98.0%
Protection      
LVRT Yes
Islanding Protection Yes
DC reverse connection protection Yes
AC short-circuit protection Yes
Leakage current protection Yes
Grid monitoring Yes
DC switch / AC switch Yes* / No
PV string current monitoring Yes
Overvoltage protection DC Type II / AC Type II
General Data      
Dimensions (W*H*D) 370*485*160 mm
Weight 20 kg
Isolation method Transformerless
Degree of protection IP65
Night power consumption < 1 W
Operating ambient temperature range -25 to 60 ℃ (> 45 ℃ derating)
Allowable relative humidity range 0 – 100 % (non-condensing)
Cooling method Natural cooling
Max. operating altitude 4000 m (> 3000 m derating)
Display/ Communication LED, Bluetooth + APP / RS485, (WiFi, E-Net optional)
DC connection type MC4 (Max. 6 mm² )
AC connection type Plug and play connector (Max. 6 mm² )
Compliance EN62109-1, EN62109-2, IEC 61727, IEC 62116, VDE 0126- 1-1/4105, AS 4777.2, EN 50438:2013, C10/11, G59/3 EN62109-1, EN62109-2, IEC 61727, IEC 62116,VDE 0126-1-1/4105,UTE C15-712- 1,VFR-2014, CEI 0-21, EN 50438:2013, C10/11, G59/3, UNE 206007-1 EN62109-1, EN62109-2, IEC 61727, IEC 62116,VDE 0126-1-1/4105,EN 50438:2013, C10/11, G59/3
Grid Support Active & reactive power control and power ramp rate control
Type designation SG5KTL-MT SG6KTL-MT SG8KTL-M