SH5.0/6.0/8.0/10RT

Smart Management
High self-consumption with optimised built-in EMS
Free online monitoring to enhance energy management for end user, installer and retailer
Remote firmware update and customisable settings
Easy Installation
Unique push-in connectors for time-saving installation
Touch free commissioning with smartphone
Lightweight and compact
Flexible Application
150~600V wide battery voltage range
Supports parallel connection with full
communication between inverters
Provides 100% unbalance loads in backup mode
Energy Independence
Seamless transition to backup mode for protection against power outages
Fast charging/discharging to meet the demand of higher consumption and energy trading

Technical Data

Protection
LVRT Yes
Anti-islanding protection Yes
AC short circuit protection Yes
Leakage current protection Yes
DC switch (solar) Yes
DC fuse (battery) Yes
Overvoltage Protection DC Type II / AC Type II
System Data
Max. efficiency / European efficiency 98.0% / 97.2%
98.2% / 97.5%
98.4% / 97.9%
98.4% / 97.9%
Max. charge / discharge efficiency 98.5%
Isolation method (solar) / (battery) Transformerless / Transformerless
Ingress protection rating IP65
Operating ambient temperature range -25 ℃– 60 ℃ (>45 ℃ derating)
Allowable relative humidity range 0%~100%
Cooling method Natural convection
Max. operating altitude 4000m (>2000m derating)
Display LED, Graphic LCD (Optional)
Communication RS485, Wi-Fi, Ethernet, 1 * Digital Output, 4 * Digital Input
DC connection type MC4 (PV) / Sunclix (Battery)
AC connection type Plug and play connector
Compliance IEC / EN 62109-1, IEC / EN 62109-2,IEC / EN 61000-3-11, IEC / EN 61000-3-
12, EN 62477-1, VDE0126-1-1 / 4105, CEI 0-21, AS 4777.2, EN50438
Mechanical Data
Dimensions (W * H * D) 480 * 540 * 170 mm
Mounting method Wall-mounting bracket
Weight 25 kg
PV Input Data
Max. PV input power 6600 W
8000 W
10600 W
13300 W
Max. PV input voltage 1100 V
1100 V
1100 V
1100 V
Startup voltage 180
250
250
250
Nominal input voltage 600 V
600 V
600 V
600 V
MPP voltage range 150 V-1000 V
200V-1000 V
200V-1000 V
200V-1000 V
MPP voltage range for nominal power 210 V-850 V
250 V-850 V
330 V-850 V
280 V-850 V
No. of MPPTs 2
Max. number of PV strings per MPPT 1 / 1
1 / 1
1 / 1
1 / 2
Max. PV input current 25 A (12.5 A / 12.5 A)
25 A (12.5 A / 12.5 A)
25 A (12.5 A / 12.5 A)
37.5A (12.5 A / 12.5 A)
Max. current for input connector 16 A
Short-circuit current of PV input 32 A (16 A / 16 A)
32 A (16 A / 16 A)
32 A (16 A / 16 A)
48 A (16 A / 32 A)
AC Input and Output Data
Max. AC apparent power 5000 VA
6000 VA
8000 VA
10000 VA
Nominal AC ouput current 7.3 A
8.7 A
11.6 A
14.5 A
Max. AC output current 8.5 A
10A
13.5A
17A
Nominal AC voltage 3 / N / PE, 220 / 380 V; 230 / 400 V; 240 / 415 V
AC voltage range 270-480 Vac (this may vary with grid standards)
Nominal grid frequency 50 Hz / 60 Hz, 45-55 Hz
Grid frequency range 55-65 Hz (this may vary with grid standards)
THD <3 % (of nominal power)
DC current injection <0.5 % (of nominal current)
Power factor >0.99 at default value at nominal power
(adj. 0.8 overexcited / leading o 0.8 underexcited / lagging)
Battery Data
Battery type Li-ion battery
Battery voltage 150 V–600 V
Max charge / discharge current 25 A / 25 A
Max charge / discharge power 6600 W
8000 W
10600 W
10600 W
Backup Data
Nominal voltage 3 / N / PE,220 / 380V;230 / 400V;240 / 415V
Frequency range 50 Hz / 60 Hz (±0.2 %)
Total hamonic factor output voltage 2 % (full resistive load)
Switch time to emergency mode <20ms
Nominal output power 5000 W / 5000 VA
6000 W / 6000 VA
8000 W / 8000 VA
10000 W / 10000 VA
Peak output power 6000 W / 6000 VA,
5 min
10000 W / 10000 VA, 10 s

7200 W / 7200 VA,
5 min
10000 W / 10000 VA, 10 s

12000 W / 12000 VA,
5 min

12000 W / 12000 VA,
5 min
Parallel operation Yes

Product Consultation